1. Power generation control mode

1491027793431785.jpg

Load mode selection for the power generation control mode, when the remote start input on demand is valid, the unit starts, synchronous closing soft loading, output is set the active power, reactive power or power factor. When the remote start is invalid, the unit soft unloading,open and shutdown.

2.Mains control mode

1491027801637786.jpg

Load mode selection for the mains control mode, when the remote start input on demand is valid, the mains input power is greater than the set value, the unit starts, synchronous closing, power soft loading, according to set the mains load power value, beyond themains, the part of the electrical power setting is made up of the power. When the remote start is invalid or the load is less than the mains power setting, the unit soft unloading open and shut down. The mains control mode must be connected to the mains CT.

3.Load receiving mode

Load mode selection for the load receiving mode, when the remote start input on demand is valid, the unit starts, synchronous closing, power soft loading, power all transferred to the power generation side, the mains close. When the remote start is invalid, the mains anti-synchronous closing, power generation all transferred to the mains, power generation open and shut down. The load receiving mode must be connected to the mains CT.

Note: This mode applies to port units.

4.AMF control mode

After the failure of the mains, the mains open, the unit starts with the load. After the mains is normal, the mains anti-synchronous closing, power soft unloading, the unit automatically shuts down.

5. Islanding control mode

Remote start island mode is valid, the unit starts, synchronous closing soft loading,mains opening. Remote start island mode is invalid, the mains anti-synchronous closing, power soft unloading, the unit automatically shuts down.







SmartGen Internet +



Cloud Monitoring Platform

Control your genset at any time


English WeChat Service

Scan QR code to get information in time


SmartGen Products APP

Get products information in real time


Smartgen Media

Acquire trends of SmartGen at any time











WEB:中文·繁体·English

TEL:0086-371-67988888/67981888  FAX:0086-371-67992952

ADD:No.28 Jinsuo Road, Zhengzhou City, Henan Province, China

E-MAIL:sales@smartgen.cn

Copyright© Since 1998 SmartGen

豫ICP备11033962号-1




HAND-IN-HAND WITH YOU, WIN-WIN IN FUTURE.