HAT530NCSuitable for NO Breaking ATS and ONE Breaking ATS-Smartgen,Genset Controller,Generator Controller,ATS Controller,panel manufactory,ats manufaction,battery charger manufactory 










HAT530NC


HAT530NC ATS Controller is composed of the core microprocessor, which can precisely measure 3-phase/single phase voltage of 2 ways, make accurate judgment on abnormal voltage (power lost, over/under voltage, over/under frequency, loss of phase, phase sequence wrong), and control ATS to transfer after delay is expired. This controller is suitable for NO Breaking ATS and ONE Breaking ATS. When #1 power is abnormal, the controller will send signal to start genset after the “#1 abnormal delay” has expired. “Three remotes” (remote control, remote measurement and remote communication) functions can be implemented with the help of RS485 communication port.




Product Code:6020052

Power Supply:AC(170~277)V

Case Dimensions:139*120*50(mm)

Panel Cutout:130*111(mm)

Operating Temp. :(-25~+70)℃

Weight:0.51kg





HAT530NC ATS Controller is composed of the core microprocessor, which can precisely measure 3-phase/single phase voltage of 2 ways, make accurate judgment on abnormal voltage (power lost, over/under voltage, over/under frequency, loss of phase, phase sequence wrong), and control ATS to transfer after delay is expired. This controller is suitable for NO Breaking ATS and ONE Breaking ATS. When #1 power is abnormal, the controller will send signal to start genset after the “#1 abnormal delay” has expired. “Three remotes” (remote control, remote measurement and remote communication) functions can be implemented with the help of RS485 communication port. 


PERFORMANCE AND CHARACTERISTICS

  1. Collect 2-way 3 phase Voltage and Frequency:

    1#                                2#

    Line voltage   (Uab, Ubc, Uca)    Line voltage   (Uab, Ubc, Uca)

    Phase voltage (Ua, Ub, Uc)        Phase voltage (Ua, Ub, Uc)

    Frequency    Hz                   Frequency    Hz

  2. Over/under voltage, loss of phase, phase sequence wrong, over/under frequency detection function. As default, phase reverse sequence detection and over/under frequency detection are disable; however, users can set the function as you need. 

  3. Controller running parameters can be set by upper computer testing software; At using, controller RS485 port shall connect upper computer by SG72 port module (USB transfers to RS485) or other transfer module. 

  4. Normal delay of 1# power or 2# power can be set (Range: 0-60s); Genset crank delay can be set (Range: 0-3600s). 

  5. Abnormal delay of 1# power or 2# power can be set (Range: 0-60s); Genset stop delay can be set (Range: 0-3600s). 

  6. “1# power priority”, “Auto/Manual”, “No priority” and “2# power priority” can be set via controller front panel, to realize 1# power priority, 2# power priority or no priority to supply power. 

  7. Close output can be set to pulse or continuous output. 

  8. 2-way N wire isolated design. 

  9. Auto/Manual mode transfer. In manual mode, ATS transfer can be implemented via panel pushbutton. 

  10. LEDs mounted on front panel can clearly show ATS running status.

  11. Forced Open input port has been designed; When the input port is active, the switch will be Breaking position forcedly (woks only for the ATS with Breaking Position).

  12. AUX.OUTPUT 1 and AUX.OUTPUT 2 can be configured to make it easy to transfer power supply.

  13. The output contact capacity of 1# and 2# power supply transfer relay (1#CLOSE, 2#CLOSE, OPEN) is 5A AC250V, passive contact, can be directly used in driving switch to transfer.

  14. The output contact capacity of Genset start relay (GENS START) is 7A AC250V/7A DC28V, passive N/C contact.

  15. Suitable for various AC systems (3 phase 4-wire, 2-phase 3-wire and single-phase 2-wire).

  16. Modular design, retardant ABS plastic shell, pluggable terminal, built-in mounting,compact structure with easy installation. 



Function Item Parameter
Display LED
AC System 1P2W/2P3W/3P4W
Alternator Voltage (170~277)V(ph-N)
Alternator Frequency 50/60Hz
Monitor Interface RS485
Programmable Interface RS485
Switch Over Priority
Applicable Switch Type NO Breaking ATS and ONE Breaking ATS
Case Dimensions(mm) 139*120*50
Panel Cutout(mm) 130*111
Operating Temp. (-25~+70)℃




No Video


Data Type Version Download Link
Chinese Manual V1.0 View Online   Download
English Manual V1.0 View Online   Download
Software V1.1.0.1 Download
Typical Application Download
3D Model Diagram Download


Products accumulated comments (0)






Company impression:

Product quality:

Service evaluation:

Phone or E-mail:

   



Application Cases related to this product (0)








SmartGen Internet +



Cloud Monitoring Platform

Control your genset at any time


English WeChat Service

Scan QR code to get information in time


SmartGen Products APP

Get products information in real time


Smartgen Media

Acquire trends of SmartGen at any time











WEB:中文·繁体·English·Taobao

TEL:0086-371-67988888/67981888  FAX:0086-371-67992952

ADD:No.28 Jinsuo Road, Zhengzhou City, Henan Province, China

E-MAIL:sales@smartgen.cn

Business Partner:Woodward

Copyright© Since 1998 SmartGen




Smartgen Media:Facebook . Twitter . Linkedin . Odnoklassniki . VK . Reddit . Medium . Blogger . Wordpress . Tumblr . Ameba . Naver . YouTuBe . Pinterest . Site123 . Nifty . Mix Wixsite


HAND-IN-HAND WITH YOU, WIN-WIN IN FUTURE.